Sara Drago
University of Genoa · 2 papers here · 2 ideas from their work
View on OpenAlex ORCID 0000-0002-9897-8079
Ideas from their papers
- Full-Arch TAD Guide Generator with Evidence-Based Safety Margins
A digital workflow tool for orthodontic labs that generates full-arch 3D-printed surgical guides for palatal TAD insertion, with safety margins sized to measured guide deviations — sub-millimeter at the entry point but up to roughly 1.3 mm at the screw tip. A new systematic review and multiple accuracy studies corroborate that full-arch guided placement outperforms freehand insertion and skeletonized designs, though skeletonized guides remain clinically acceptable, so the tool is positioned for precision-critical cases. The workflow requires CBCT-based planning, since cephalogram-only references measurably underestimate distances to teeth.
- Aligner Material Stability Certification Service
A specialized testing and certification service for aligner manufacturers that validates the mechanical stability and biocompatibility of materials after simulated oral exposure. The service provides standardized data on material degradation and chemical leaching to ensure patient and clinician safety.
Related ideas
Close to their work, not derived from it.
- Dynamic-Force 3D Printed Aligner Resin
A specialized 3D-printable resin for aligners that provides a lower, more consistent orthodontic force profile compared to traditional thermoformed plastics.
- Full-Arch Precision TAD Guide System
A high-stability 3D-printed surgical guide that uses full-arch geometry to minimize translational and rotational deviations during orthodontic TAD placement, aligning the physical drill path with the digitally planned one. Studies of guided and navigation-assisted mini-implant placement show significantly lower angular and positional deviations than freehand insertion, and printed guides achieve accuracy comparable to conventional fabrication. Because resin safety is protocol-dependent, the system uses certified biocompatible resins with locked, manufacturer-specified print and post-cure workflows.
- Bio-Optimized 3D-Printed Aligner Resin
A 3D-printable resin for clear aligners built on urethane-dimethacrylate (UDMA) monomers with the common diluent TEGDMA reduced or replaced, designed to leach fewer unreacted monomers and break down more slowly under saliva enzymes. The first version is a drop-in bottle of resin for existing SLA/DLP printers, sold to orthodontic labs that already direct-print aligners. Its case rests on measured data — degree of conversion and enzyme-challenge leaching tests — rather than force or stiffness claims.
- Adduct-Map Genotoxicity Screen for Direct-Print Aligner Resins
A lab testing service that checks whether chemicals leaching out of 3D-printed dental aligners chemically bind to and modify DNA, using an adduct-detection method originally proven for the chemotherapy drug cisplatin. It gives aligner resin makers a regulatory-grade genotoxicity report no current dental test provides.
- Water-Compensated Direct-Print Aligner Geometry Engine
A CAD module for direct-printed dental aligner workflows that adds local thickness to offset the force lost as the resin absorbs water and relaxes under load, so the aligner keeps delivering the intended force across its wear period. New studies confirm the cubic thickness-to-force relationship and show direct printing realizes thickness far more precisely than thermoforming, but also that force decays from in-wear stress relaxation within hours and that custom geometry must stay within manufacturer-validated print and post-cure limits for safety. The engine therefore targets a force-over-time profile, caps compensation within validated post-cure windows, and initially supports only certified resins.
- Hydro-Stable Aligner Coating
A medical-grade hydrophobic coating for 3D-printed aligners to prevent water sorption and the resulting loss of mechanical stiffness.
- Bio-Active Anti-Biofilm 3D Aligner Resin
A specialized 3D-printing resin for clear aligners infused with chitosan nanoparticles to reduce bacterial adhesion and Streptococcus mutans biofilm biomass — the main hygiene weakness of direct-printed aligners. A new critical review confirms that leading direct-print resins are non-cytotoxic and BPA-free, providing a safe base chemistry, while flagging biofilm adhesion as a critical open problem the category has not solved. The product's value proposition is antimicrobial performance for high-caries-risk patients, not force delivery or mechanical tuning.
- Precision-Force Aligner Design Tool
A CAD add-on for orthodontic design software that computes the aligner thickness, print material, and gingival trimline needed to hit a clinician's target 'gentle' force profile, using measured force and stress-relaxation data for direct-printed resins. New in-vitro evidence shows printed aligners — especially with garlanded trimlines — deliver significantly lower, more controlled forces than thermoformed ones, while pilot data confirm force decay differs sharply by material, so the tool models each resin's relaxation curve. An iterative simulation loop accounts for the large force drop-off over successive tooth movements (PDL stress fell ~90% in FEA studies), and emerging sensor-equipped aligners offer a way to check predicted forces against real in-mouth measurements.