Seedlabs
Source research

Airway obstruction in competitive swimmers

Marja Kristiina Päivinen, Tuula Putus, Pentti Kalliokoski, Heikki Olavi Tikkanen · 2013 · 3 citationsRead the paper

Background: Swimming has been shown to cause beneficial effects on lung function. However, increased adverse effects have been hypothesized due to the air quality of indoor swimming pools. Objectives: To compare competitive swimmers present lung function to swimmers twenty to thirty years ago and examine the associations between lung function and medical history and reported respiratory symptoms in present swimmers. Methods: One hundred swimmers, 47 females and 53 males were studied with flow-volume spirometry. These findings were compared with ones obtained 20 - 30 years ago among 98 swimmers, 40 females and 58 males. Forced expiratory volume in one second (FEV1), forced expiratory volume (FVC) and their ratio (FEV%) were analysed for airways obstruction. Associations between lung function and asthma, allergy, and respiratory symptoms were examined using questionnaire. In addition airways inflammation was measured with exhaled nitric oxide measurement (FENO) in present swimmers. Airborne trichloramine was measured in air of indoor swimming pools. Results: Airway obstruction was found in 15%, 15 out of 100 studied swimmers, which all reported physician diagnosed asthma and/or family history of asthma. Most, 12 out of 15 of swimmers with obstruction finding, were males. Twenty to thirty years ago obstruction was found in 17 of the 98 swimmers. Airborne concentrations of trichloramine in the present swimming pools, were low, less than 0.1 mg/m3. Conclusion: Airway obstruction was associated with asthma and family history of asthma. There was no increase in obstruction findings among competitive swimmers within 2 - 3 decades. Measured concentrations of trichloramine raised no concern on swimmers health.

What the full text shows

Tested in real conditions
  • Airway obstruction prevalence in present competitive swimmers was similar to those from 20-30 years ago. — 15% (15/100) vs 17.3% (17/98) (Competitive swimmers)
  • Airway obstruction was exclusively associated with a history of asthma. — 100% of obstructed swimmers reported physician diagnosed asthma and/or family history of asthma (Present competitive swimmers)
  • Present swimmers showed significantly higher lung function values compared to swimmers from 20-30 years ago. — FVC 111% vs 99%, FEV1 111% vs 107%, FEV% 97% vs 93% of predicted (Comparison of present vs historical cohorts)
  • Airborne trichloramine concentrations in training pools were below critical health thresholds. — < 0.1 mg/m3 (critical level is 0.5 mg/m3) (Indoor swimming pools used by present swimmers)
  • Swimmers reporting respiratory symptoms had significantly lower FEV% and higher FENO levels than non-symptomatic swimmers. — FEV% 95% vs 99% (p=0.014); FENO 19 ppb vs 14 ppb (p=0.001) (Present competitive swimmers)
Setup
100 present competitive swimmers (47F/53M, mean age 17) compared to 98 historical swimmers (40F/58M, mean age 14).
How
Flow-volume spirometry, exhaled nitric oxide (FENO) measurements, and structured questionnaires were used on a current cohort and compared to historical data. Airborne trichloramine was measured using impregnated quartz filters and ion chromatography.
Limitations
Flow-volume spirometry may not be sensitive enough to detect early-phase pulmonary disease in small airways. · Small sample size for the subgroup with airway obstruction (n=15).

Summarized by Gemma 4 from the open-access full text · 29 Oct 2026. Read it