Seedlabs
Source research

ATR-FTIR Analysis and One-Week Stress Relaxation of Four Orthodontic Aligner Materials

Florina Jaggy, Spiros Zinelis, Georgios Polychronis, Raphael Patcas, Marc Andreas Schätzle, George Eliades et al. · 2020 · 34 citationsRead the paper

The aim of this study was to estimate possible differences in the chemical composition and relaxation of orthodontic aligner materials. Four commercially available thermoplastic materials CAM (Scheu-Dental, Iserlohn, Germany), COP (Essix, Dentsply Raintree Essix Sarasota,FL, USA), DUR (Great Lakes Dental Technologies, Tonawanda, NY) and ERK (Erkodent Erich Kopp, Pfalzgrafenweiler Germany) were included in this study. Rectangular strips from each material were prepared according to the manufacturer's instructions and subjected to attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy and stress relaxation characterization. The reduction in applied stress (RAS) after one week was estimated and statistically analyzed by one-way ANOVA at the 0.05 level of significance. All specimens were subjected to optical microscopy before and after stress relaxation testing under transmittance polarized illumination. ATR-FTIR microscopy revealed that all materials are made of polyethylene terephthalate glycol (PETG) while no significant differences were identified in RAS values among materials tested, which ranged from 6%-10% (p ≥ 0.05). All samples illustrated the developments of shear bands during relaxation testing according to optical microscopy findings. The tested materials illustrated similar chemical composition and relaxation behavior and thus no differences in their clinical efficacy are anticipated.

What the full text shows

Shown in the lab
  • All tested orthodontic aligner materials are composed of polyethylene terephthalate glycol (PETG). (ATR-FTIR spectroscopy)
  • Reduction in applied stress (RAS) after one week showed no statistically significant difference between the four materials. — 6%-10% RAS (Initial stress of 2.1 MPa over 168 hours)
  • Intermolecular bonding (Ri index) varied across materials, with COP showing the highest bonding. — COP=1.63, DUR=1.46, ERK=1.45, CAM=1.41 (Peak fitting analysis of carboxyl groups (1650–1750 cm-1))
  • All materials developed shear bands (strain localization) during relaxation testing. — 45° orientation to the long axis (Optical microscopy under transmittance polarized illumination)
Setup
Four thermoplastic materials (CAM, COP, DUR, ERK); rectangular strips (30 x 4 x 0.3-0.5 mm) pressed over dental stone models; initial stress of 2.1 MPa.
How
Materials were analyzed using ATR-FTIR spectroscopy for chemical composition and a custom-made load cell unit to measure stress relaxation over one week. Optical microscopy was used to observe structural changes before and after relaxation.
Limitations
In vitro study cannot adequately simulate the multifaceted intraoral aging milieu. · The relationship between shear band development and stress fluctuations is an assumption requiring further testing.

Summarized by Gemma 4 from the open-access full text · 16 Nov 2026. Read it