Seedlabs
Source research

First Results from CUORE: A Search for Lepton Number Violation via 0νββ Decay of Te130

Christopher Alduino, F. Alessandria, K. Alfonso, Erica Andreotti, Claudio Arnaboldi, Frank T. Avignone III et al. · 2018 · 315 citationsRead the paper

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number-violating process: ^{130}Te neutrinoless double-beta decay. Examining a total TeO_{2} exposure of 86.3 kg yr, characterized by an effective energy resolution of (7.7±0.5) keV FWHM and a background in the region of interest of (0.014±0.002) counts/(keV kg yr), we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T_{1/2}^{0ν}(^{130}Te)>1.3×10^{25} yr (90% C.L.); the median statistical sensitivity of this search is 7.0×10^{24} yr. Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T_{1/2}^{0ν}(^{130}Te)>1.5×10^{25} yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find m_{ββ}<(110-520) meV, where the range reflects the nuclear matrix element estimates employed.

What the full text shows

Tested in real conditions
  • Lower limit on the half-life of 0νββ decay of 130Te — >1.3×10^{25} yr (90% C.L.) (CUORE data with 86.3 kg yr exposure)
  • Combined lower limit on the half-life of 0νββ decay of 130Te — >1.5×10^{25} yr (90% C.L.) (Combined CUORE, CUORE-0, and Cuoricino data)
  • Limit on the effective Majorana neutrino mass — < (110-520) meV (Based on combined half-life limit and various nuclear matrix element estimates)
  • Background rate in the region of interest — (0.014±0.002) counts/(keV kg yr) (CUORE detector array)
  • Effective energy resolution at Qββ — (7.7±0.5) keV FWHM (CUORE detector array)
Setup
988 TeO2 crystals (5x5x5 cm3, 750g each) arranged in 19 towers, cooled by a 3He/4He dilution refrigerator with lead and polyethylene shielding.
How
The researchers used a ton-scale cryogenic bolometer array of TeO2 crystals cooled to 15 mK to search for a peak in the summed energy spectrum at the Q-value of 130Te decay. They employed profile likelihood and frequentist analyses to determine half-life limits and neutrino mass constraints.
Limitations
Energy resolution is currently 7.7 keV, with a goal to reach 5 keV · Sensitivity is limited by the background rate in the region of interest

Summarized by Gemma 4 from the open-access full text · 9 Nov 2026. Read it