Non‐lethal loop‐mediated isothermal amplification assay as a point‐of‐care diagnostics tool for Neoparamoeba perurans, the causative agent of amoebic gill disease
Irene Cano, Robin McCullough, Brian Mulhearn, Susie Gunning, Ava Waine, Claire L. Joiner et al. · 2020 · 6 citationsRead the paper
Abstract Neoparamoeba perurans is the causative agent of amoebic gill disease (AGD). Two loop‐mediated isothermal amplification (LAMP) assays targeting the parasite 18S rRNA and the Atlantic salmon EF1α, used as internal control, were designed. The N. perurans LAMP assay did not amplify close relatives N. pemaquidensis and N. branchiphila, or the host DNA. This assay detected 106 copies of the parasite 18S rRNA gene under 13 min and 103 copies under 35 min. Five “fast‐and‐dirty” DNA extraction methods were compared with a reference method and further validated by TaqMan™ qPCR. Of those, the QuickExtract buffer was selected for field tests. Seventy‐one non‐lethal gill swabs were analysed from AGD‐clinically infected Atlantic salmon. The pathogen was detected under 23 min in fish of gill score >2 and under 39 min for lower gill scores. About 1.6% of the tests were invalid (no amplification of the internal control). 100% of positives were obtained from swabs taken from fish showing gill score ˃3, but only ~50% of positives for lower gill scores. The present LAMP assay could be implemented as a point‐of‐care test for the on‐site identification of N. perurans; however, further work is required to improve its performance for lower scores.
What the full text shows
Working prototype- The LAMP assay detected N. perurans with a limit of detection (LOD) of 10^3 copies of the 18S rRNA gene. — 10^3 copies under 35 min (Recombinant plasmid template)
- The assay showed high specificity, with no amplification of close relatives N. pemaquidensis, N. branchiphila, or host DNA. (In silico and in vitro testing)
- QuickExtract was identified as the most effective point-of-care (POC) DNA extraction method. — Tp 18:45 vs 12:45 for reference method (Amoeba-soaked swabs)
- The POC assay achieved 100% detection in fish with high gill scores. — 100% positive for gill score >3 (Non-lethal gill swabs from challenged Atlantic salmon)
- The POC assay showed reduced sensitivity for fish with low gill scores. — ~50% positive for lower gill scores (Non-lethal gill swabs from challenged Atlantic salmon)
- The POC test is significantly cheaper than TaqMan qPCR. — £2.5 per sample vs £6.8 (Including extraction and amplification)
- Setup
- 71 non-lethal gill swabs from naturally infected Atlantic salmon and 60 swabs from challenged Atlantic salmon (200g each).
- How
- Designed a LAMP assay targeting N. perurans 18S rRNA and an internal control targeting Atlantic salmon EF1α. Compared five 'fast-and-dirty' DNA extraction methods against a reference laboratory method and validated results using TaqMan qPCR.
- Limitations
- Reduced sensitivity for fish with low visual gill scores (score <3). · Potential for non-specific amplicons when target copies are <100. · Presence of contaminants in POC DNA extractions (low 260/230 ratio).
Summarized by Gemma 4 from the open-access full text · 8 Nov 2026. Read it