Clinical validation of an automatic atlas‐based segmentation tool for male pelvis CT images
Marta Casati, Stefano Piffer, Silvia Calusi, L. Marrazzo, Gabriele Simontacchi, Vanessa Di Cataldo et al. · 2022 · 17 citationsRead the paper
PURPOSE: This retrospective work aims to evaluate the possible impact on intra- and inter-observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto-segmentation tool in radiotherapy planning workflow. METHODS: Tests were carried out on five structures (bladder, rectum, pelvic lymph-nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re-contour and edit auto-contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto-contours, producing automatic-modified (AM) contours. The procedure was repeated to evaluate intra-observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra- and inter-observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as "clinically acceptable" or "to be corrected" in a blind test. RESULTS: Comparing AM to M sets, a significant reduction of both inter-observer variability (p < 0.001) and contouring time (-45% whole pelvis, p < 0.001) was obtained. Intra-observer variability reduction was significant only for bladder and femoral heads (p < 0.001). The statistical test showed no significant bias. CONCLUSION: Our atlas-based workflow proved to be effective for clinical practice as it can improve contour reproducibility and generate time savings. Based on these findings, institutions are encouraged to implement their auto-segmentation method.
What the full text shows
Working prototype- Reduction in whole pelvis contouring time when using auto-segmentation followed by manual editing. — -45% vs. manual contouring (Average across 5 ROs and 6 test subjects)
- Reduction in inter-observer variability for all regions of interest (bladder, rectum, pelvic lymph-nodes, femoral heads). — p < 0.001 for DSC and MDA (Compared to manual contouring)
- Reduction in intra-observer variability for specific structures. — p < 0.001 for bladder and femoral heads (Compared to manual contouring)
- No statistically significant reduction in intra-observer variability for specific structures. — No significant difference (Rectum and pelvic lymph-nodes)
- Reduction in the 95th percentile of Mean Distance to Agreement (MDA) for specific structures. — Bladder: 1.0 to 0.7 mm; PLN: 3.2 to 1.5 mm; Femoral heads: 1.1 to 0.4 mm and 1.0 to 0.6 mm (M to AM contours)
- Setup
- 6 test subjects, 5 radiation oncologists, 5 structures (bladder, rectum, pelvic lymph-nodes, femoral heads), 600 total contours.
- How
- A multi-subject atlas-based segmentation tool (MIM MAESTRO) was used to generate contours for five structures in male pelvis CTs. Five radiation oncologists performed manual contouring (M) and editing of auto-contours (AM) twice each to evaluate intra- and inter-observer variability and time savings.
- Limitations
- Small sample size (6 patients, 5 ROs). · Retrospective study design. · Lack of intra-observer reduction for rectum and PLN attributed to intrinsic delineation uncertainty and poor contrast.
Summarized by Gemma 4 from the open-access full text · 13 Nov 2026. Read it