Standardisation and international adoption of defined approaches for skin sensitisation

Silvia Casati, David Asturiol, Patience Browne, Nicole Kleinstreuer, Michèle Régimbald-Krnel, Pierre Therriault · 2022 · 18 citationsRead the paper

In the absence of stand-alone one-to-one replacements for existing animal tests, efforts were made to integrate data from in silico, in chemico and in vitro methods to ensure sufficient mechanistic coverage of the skin sensitisation Adverse Outcome Pathway (AOP) and generate predictions suitable for hazard identification and potency sub-categorisation. A number of defined approaches (DAs), using fixed data interpretation procedures (DIP) to integrate data from multiple non-animal information sources, were proposed and documented using a standard reporting template developed by the Organisation for Economic Co-operation and Development (OECD). Subsequent international activities focused on the extensive characterisation of three of these DAs with respect to the reference in vivo data, applicability domains, limitations, predictive performances and characterisations of the level of confidence associated with the predictions. The ultimate product of this project was an OECD Guideline that provides information equivalent to that provided by the animal studies and that can be used to satisfy countries' regulatory data requirements for skin sensitisation. This Defined Approach Guideline was the first of its kind for the OECD, and provides an important precedent for regulatory adoption of human biology-relevant new approach methodologies with performances equivalent to, or better than, traditional animal tests. This mini review summarizes the principal features of the defined approaches described in OECD guideline 497.

What the full text shows

Deployed in practice
  • DAs showed balanced accuracies (BA) for discriminating sensitisers vs non-sensitisers against LLNA data. — 80–84% BA (High confidence predictions only)
  • DAs showed balanced accuracies (BA) for discriminating sensitisers vs non-sensitisers against human reference data. — 69–88% BA (High confidence predictions only)
  • ITSv1 and ITSv2 DAs achieved overall accuracies for UN GHS potency sub-categorization (1A, 1B, NC) against LLNA data. — 71% overall accuracy; 77–78% BA (High confidence predictions only)
  • ITSv1 and ITSv2 DAs achieved overall balanced accuracies for UN GHS potency classification against human reference data. — 72–73% BA (High confidence predictions only)
  • ITSv1 and ITSv2 DAs correctly predicted nearly all pre/pro-haptens. — Essentially all correct (ITSv2 had one inconclusive) (Dataset of 29 putative pre/pro-haptens)
  • The 2o3 DA showed sensitivity for pre/pro-haptens. — 83% sensitivity (Dataset of 29 putative pre/pro-haptens)
Setup
Curated dataset of 168 chemicals with LLNA data (135 sensitisers, 33 non-sensitisers) and a database of Human Predictive Patch Test (HPPT) studies.
How
Integration of in silico, in chemico, and in vitro data using fixed data interpretation procedures (DIPs) across three Defined Approaches (2o3, ITSv1, ITSv2). These combine the DPRA, KeratinoSens™, h-CLAT, and in silico tools (Derek Nexus or OECD QSAR Toolbox).
Limitations
Testing of mixtures is currently not within the applicability domain. · Results falling within statistically derived borderline ranges are of lesser confidence. · Some in silico negative predictions may be outside the applicability domain if they contain misclassified features.

Summarized by Gemma 4 from the open-access full text · 27 Nov 2026. Read it