Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis
Xinwei Lyu, Xing Cao, Luxian Chen, Yuyao Liu, Huilin Li, Chenglong Hu et al. · 2023 · 24 citationsRead the paper
BACKGROUND: The biomechanics generated by the clear aligner (CA) material changes continuously during orthodontic tooth movement, but this factor remains unknown during the computer-aid design process and the predictability of molars movement is not as expected. Therefore, the purpose of this study was to propose an iterative finite element method to simulate the long-term biomechanical effects of mandibular molar mesialization (MM) in CA therapy under dual-mechanical systems. METHODS: Three groups including CA alone, CA with a button, and CA with a modified lever arm (MLA) were created. Material properties of CA were obtained by in vitro mechanical experiments. MM was conducted by the rebound force exerted by CA material and the mesial elastic force (2N, 30° to the occlusal plane) applied to the auxiliary devices. Stress intensity and distribution on periodontal ligament (PDL), attachment, button and MLA, and displacement of the second molar (M2) during the iterations were recorded. RESULTS: There was a significant difference between the initial and cumulative long-term displacement. Specifically, compared to the beginning, the maximum stress of PDL decreased by 90% on average in the intermediate and final steps. The aligner was the main mechanical system at first, and then, the additional system exerted by the button and MLA dominated gradually. The stress of attachments and auxiliary devices is mainly concentrated on their interfaces with the tooth. Additionally, MLA provided a distal tipping and extrusive moment, which was the only group that manifested a total mesial displacement of the root. CONCLUSIONS: The innovatively designed MLA was more effective in reducing undesigned mesial tipping and rotation of M2 than the traditional button and CA alone, which provided a therapeutic method for MM. The proposed iterative method simulated tooth movement by considering the mechanical characteristic of CA and its long-term mechanical force changes, which will facilitate better movement prediction and minimize the failure rate.
What the full text shows
Shown in the lab- The Modified Lever Arm (MLA) reduced undesigned mesial tipping and rotation of the second molar (M2) compared to CA alone. — Mesial tipping decreased by 0.491° and rotation by 0.899° vs. CA alone (Iterative FEA simulation of mandibular molar mesialization)
- MLA was the only configuration to achieve total mesial displacement of the root. — Initial root displacement +0.0228 mm changed to final displacement -0.0215 mm (Iterative FEA simulation of mandibular molar mesialization)
- Maximum PDL stress decreased significantly over the course of the iterative movement. — 90% average decrease in intermediate and final steps vs. initial step (Across all three configurations (CA, button, MLA))
- The traditional button was inefficient in relieving mesial tipping and increased lingual inclination. — Lingual tipping increased by 0.088° (Compared to CA alone)
- Maximum stress on the button decreased drastically over the iterations. — 98.6% reduction (1.602E+09 Pa to 2.186E+07 Pa) (From initial to final step)
- Setup
- Patient-specific model of a 25-year-old woman reconstructed from CBCT and optical scanning (6.9-μm accuracy); 0.75-mm thick Duran CA thermoplastic sheets; 2N mesial elastic force applied at 30° to the occlusal plane.
- How
- The study used an iterative finite element analysis (FEA) combining in vitro tensile testing of thermoplastic sheets with a patient-specific geometric model. It simulated long-term tooth movement through a two-step cycle of initial displacement and periodontium remodeling across three configurations: CA alone, CA with a button, and CA with a modified lever arm (MLA).
- Limitations
- The alveolar bone was excluded from the FE model and treated as a rigid surface. · Material properties of teeth and auxiliary devices were assumed to be homogeneous and isotropic. · The study is a simulation based on a single patient's anatomy.
Summarized by Gemma 4 from the open-access full text · 8 Oct 2026. Read it