Titanium allergy: diagnostic challenge in dental pre-implant surgery patch testing
Iliyana Stoeva, Zlatina Tomova · 2025 · 3 citationsRead the paper
Introduction : Titanium dental implants are the most common type of dental implants. Although titanium and its alloys are considered biocompatible, there are concerns about the induction of metal allergy with dental implants. Aim : To evaluate the presence of titanium sensitization by patch testing in patients who intend to have titanium dental implants. Materials and methods : A retrospective study was performed in which data on sensitization to titanium collected from the Allergy Office at the Faculty of Dentistry in Plovdiv from January 2022 to April 2024 were analyzed. We analyzed data from 95 patients who had patch testing done before their dental implant surgery. Results : Thirty-eight (40.0%) patients exhibited positive patch test reactions to at least one metal. The most common allergen was nickel (32.6%). Titanium (IV) oxalate was the only one with a positive rate (7.4%) among titanium reagents. Almost one-half (42.9%) of the patients were monosensitized to titanium (IV) oxalate. No association between positive reaction to titanium (IV) oxalate and history of suspected metal allergy was identified ( p =0.064). Conclusions : The absence of positive reactions to other titanium reagents, as well as a correlation with a history of metal allergy and other allergies in patients who tested positive for titanium oxalate, makes determining the clinical relevance of the positive reactions difficult. Standardization in titanium allergy research is required to ensure the accuracy of the findings.
What the full text shows
Shown in the lab- Prevalence of titanium sensitization among patients scheduled for dental implants. — 7.4% (Tested with titanium (IV) oxalate)
- Patients exhibiting positive reactions to at least one metal allergen. — 40.0% (Total patient cohort (n=95))
- Most common metal allergen identified. — 32.6% (nickel) (Total patient cohort (n=95))
- Patients monosensitized specifically to titanium (IV) oxalate. — 42.9% (Among the 7 patients positive for titanium)
- Incidence of irritant reactions to titanium (IV) oxalate. — 21.1% (Total patient cohort (n=95))
- Association between titanium (IV) oxalate sensitization and history of suspected metal allergy. — p=0.064 (not statistically significant) (Comparison of patients with vs. without history of metal allergy)
- Setup
- 95 patients (71 women, 24 men) scheduled for dental implant surgery; mean age 48.1±13.8 years.
- How
- Retrospective analysis of patch test data using ICDRG guidelines. Patients were tested with 14 metal reagents, including four titanium compounds, with readings taken at day 2, day 3/4, and day 7.
- Limitations
- High rate of irritant reactions to titanium (IV) oxalate (21.1%) · Lack of clinical relevance identified for positive titanium oxalate reactions · Small sample size for titanium-positive subgroup (n=7)
Summarized by Gemma 4 from the open-access full text · 16 Nov 2026. Read it