Retrospective radiographic study of potential tooth root contact of orthodontic mini-implants placed at the anterior palate

S.C. Möhlhenrich, J. Steur, S. Chhatwani, K. Kniha, J. Jackowski, G. Danesh · 2026 · 2 citationsRead the paper

This retrospective radiographic study investigated the influence of orthodontic mini-implant position on the distance to adjacent teeth in lateral cephalograms and corresponding cone-beam computed tomography (CBCT) images to assess the risk of root contact during placement. Intraoral scans, lateral cephalograms and CBCT images from 34 patients were superimposed. Virtual implant placement was planned using lateral cephalograms as the reference and CBCT images as the control. Implants were simulated in median and paramedian positions at inter-implant distances of 6, 8, 10 and 12 mm. The smallest distances between implants and adjacent teeth were measured using both imaging modalities. Statistical analyses included repeated-measures analysis of variance, paired t-tests and intraclass correlation coefficients, with significance set at P ≤ 0.05. Lateral cephalograms showed decreasing distances from central incisors to canines, particularly for median-inserted implants, while CBCT images revealed increasing distances laterally for both positions. No implant-to-tooth contact was observed, with all distances exceeding 1 mm. Significant agreement between measurements from both imaging techniques was found for central and lateral incisors, but not canines. Despite lateral cephalograms underestimating actual distances, the strong correlation for incisors suggests that this method allows for reliable planning with no risk of root contact.

What the full text shows

Working prototype
  • No implant-to-tooth contact occurred in any simulated scenario. — all distances > 1 mm (Median and paramedian positions at 6, 8, 10, and 12 mm inter-implant distances)
  • Lateral cephalograms (LC) consistently underestimated the actual distances to teeth compared to CBCT. (All simulated implant positions)
  • Strong agreement (ICC) between LC and CBCT measurements for central incisors. — ICC 0.81 to 0.91 (Across all inter-implant distances (6-12 mm))
  • Poor agreement (ICC) between LC and CBCT measurements for canines. — ICC 0.13 to 0.43 (Across all inter-implant distances (6-12 mm))
  • Standardized implant lengths are not recommended due to risk of bone perforation or neurovascular canal injury. — 7-mm and 9-mm implants (General anterior palate placement)
Setup
34 patients (18 female, 16 male; mean age 17.5 years); 272 simulated placement scenarios.
How
Retrospective study superimposing intraoral scans, lateral cephalograms (LC), and CBCT images. Virtual implants were simulated in median and paramedian positions at four different inter-implant distances to measure the shortest distance to adjacent teeth.
Limitations
LC underestimates actual distances to teeth · Poor reliability of LC for planning distances to canines · Retrospective nature of the radiographic study