AgentClinic: a multimodal benchmark for tool-using clinical AI agents
Samuel Schmidgall, Rojin Ziaei, Carl Harris, Ji Woong Kim, Eduardo Pontes Reis, Jeffrey K. Jopling et al. · 2026 · 344 citationsRead the paper
Evaluating large language models (LLM) in clinical scenarios is crucial to assessing their potential clinical utility. Existing benchmarks rely heavily on static question-answering, which does not accurately depict the complex, sequential nature of clinical decision-making. Here, we introduce AgentClinic, a multimodal agent benchmark for evaluating LLMs in simulated clinical environments that include patient interactions, multimodal data collection under incomplete information, and the usage of various tools, resulting in an in-depth evaluation across nine medical specialties and seven languages. We find that solving MedQA problems in the sequential decision-making format of AgentClinic is considerably more challenging, resulting in diagnostic accuracies that can drop to below a tenth of the original accuracy. Overall, we observe that agents sourced from Claude-3.5 outperform other LLM backbones in most settings. Nevertheless, we see stark differences in the LLMs' ability to make use of tools, such as experiential learning, adaptive retrieval, and reflection cycles. Strikingly, Llama-3 shows up to 92% relative improvements with the notebook tool that allows for writing and editing notes that persist across cases. To further scrutinize our clinical simulations, we leverage real-world electronic health records, perform a clinical reader study, perturb agents with biases, and explore patient-centric metrics that this interactive environment enables.
What the full text shows
Working prototype- Claude-3.5-Sonnet achieved the highest diagnostic accuracy across benchmarks. — 62.1% ± 3.3 (AgentClinic-MedQA), 42.9% ± 3.3 (AgentClinic-MIMIC-IV) (Doctor agent with N=20 interactions)
- Sequential decision-making is significantly harder than static QA, with diagnostic accuracies dropping sharply. — below a tenth of original accuracy (Comparing MedQA static QA vs AgentClinic sequential format)
- Llama-3 showed substantial improvement when using a persistent notebook tool for note-taking. — up to 92% relative improvement (Using notebook tool across cases)
- Reducing interaction limits significantly degrades diagnostic performance. — accuracy dropped from 52% to 25% (Reducing interactions from N=20 to N=10)
- Cognitive and implicit biases reduce diagnostic accuracy, with Mixtral-8x7B being more susceptible than GPT-4. — Mixtral-8x7B normalized accuracy: 78.4% (doctor cognitive bias) to 94.5% (patient cognitive bias) (Perturbing agents with instructed biases)
- Setup
- 120 multimodal agents, 215 language agents, 260 cases from 9 specialties, and 749 multilingual cases; tested on AgentClinic-MedQA and AgentClinic-MIMIC-IV datasets.
- How
- Developed a multimodal benchmark simulating clinical environments where LLM doctor agents interact with LLM patient agents and a measurement agent to diagnose cases. Evaluated 11 LLMs across nine medical specialties and seven languages using sequential dialogue and tool-use.
- Limitations
- Simplified clinical environment lacking nurses, relatives, and physical hospital constraints. · Potential data leakage for proprietary models trained on MedQA. · Reliance on LLM-based moderator and measurement agents may introduce hallucinations. · Potential bias if the same LLM acts as both doctor and patient.
Summarized by Gemma 4 from the open-access full text · 8 Nov 2026. Read it