Fused Strain-Rate and Magnetization Quench Detection with In-Winding NV-Diamond Sensing for No-Insulation REBCO Breeder Magnets
Priyanca Ford, G L Kulcinski · 2026 · 3 citationsRead the paper
The unsolved protection problem of high-temperature-superconductor (HTS) fusion magnets is that no-insulation (NI) REBCO windings quench too slowly for terminal-voltage detection to act before the local hot spot reaches a damaging temperature: the normal zone propagates at millimetres per second, so the resistive voltage integrated along it stays small while the deposited energy density climbs. We formalise and evaluate a fused-detector scheme that does not wait for voltage. Two prompt, physically independent precursors are read inside the winding pack — the mechanical strain-rate transient as the normal zone thermally expands (1.3×10^-3 s^-1), and the local magnetization change as the screening current redistributes out of the quenched turn ( B~SI8.5 over the detection window). Each is reduced to a matched-filter window statistic; because the two modalities fail in uncorrelated ways their quadrature fusion z_F=(z_S+z_M)/2 carries a statistic whose detectability exceeds either channel. On a frozen 2×10^4-trial synthetic study in a deliberately hard, weak-fault regime the fused detector reaches an area under the receiver-operating characteristic (ROC) of 0.992 — against 0.976 for magnetization and 0.921 for strain alone — and a true-positive rate of 0.857 at the 1% false-positive rate a protection trip demands, versus 0.671 and 0.372 for the single channels. The magnetization channel is supplied by an in-winding ensemble nitrogen-vacancy (NV) diamond magnetometer with a shot-noise-limited sensitivity of 0.189 pT Hz^-1/2 at 125 bandwidth, resolving the conductor-scale quench field step at a per-shot signal-to-noise ratio of order 10^9; the same NV ensemble reads field (Zeeman) and strain (zero-field-splitting) in one front end. Tripping tens of milliseconds earlier moves the adiabatic hot-spot temperature back under its limit through the current-time (MIITs) integral. The one open engineering item — the NV sensor's neutron tolerance — is bounded by a model-fusion backup that retains precursor AUC 0.95 with the NV channel degraded by up to 39×. Every headline quantity is a frozen anchor in the Kronos physics de-risking register. This is a protection architecture at the model-and-bench stage, stated as such; it separates the breeder centrepost (16.84) and the burner plug (26.49) as the two distinct magnets they are. Key results (frozen anchors): dot = 1.3 ×10^-3; n = 2 ×10^4; shot = 1.49 ×10^9. Methods & codes: FreeGSNKE, FreeGS, OpenMC, DAGMC, Sauter. Live verification: 5 gate validator(s) with live-recompute cards (4 reproduced, 1 revised). See the Verification section and data/verification.csv. Related: Paper page · De-risking register · 3D model · Learn more about Kronos Part of the 2026 Kronos publication series; independently re-run and stamped in the Kronos de-risking register (DOI 10.5281/zenodo.22645689). All numerical values are frozen design-point anchors; see the register. Public research artifact. No proprietary, financial, or supply-chain information is included. Previous version: DOI 10.5281/zenodo.22132131. Please cite this version.